The value of MRI in the evaluation of the ACL deficient knee and in the post-operative evaluation after ACL reconstruction

1993

To evaluate the usefulness of magnetic resonance imaging (MRI) in the exploration of the anterior cruciate ligament (ACL) deficient-knee, a total of twenty-five patients with chronic instability of the knee joint and who underwent both MRI and arthroscopy were studied prospectively. Twenty-three of these patients underwent an intra-articular reconstruction of the ACL with bone-patellar tendon-bone autografts. For the ACL lesions MRI had a sensitivity of 95.8%, a specificity of 100% and a diagnostic accuracy of 97.7%. Associated bowing of the PCL was seen in 20 cases of the study group. For the associated meniscal lesions MRI had a sensitivity of 77.7%, a specificity of 94.7% and a diagnosti…

AdultJoint InstabilityMalemusculoskeletal diseasesmedicine.medical_specialtyAnterior cruciate ligamentKnee JointSensitivity and SpecificityTransplantation AutologousTendonsArthroscopymedicineHumansKneeRadiology Nuclear Medicine and imagingProspective StudiesAnterior Cruciate LigamentPost operativeAcl deficientBone TransplantationPreoperative planningmedicine.diagnostic_testbusiness.industryAnterior Cruciate Ligament InjuriesArthroscopyImaging diagnosticMagnetic resonance imagingGeneral Medicinemusculoskeletal systemMagnetic Resonance Imagingsurgical procedures operativemedicine.anatomical_structureFemaleRadiologybusinesshuman activitiesEuropean Journal of Radiology
researchProduct

Frameless Neuronavigation Applied to Endoscopic Neurosurgery

2000

Objective: We retrospectively analyzed the indications, surgical techniques, and applicability of frameless neuronavigation to endoscopic procedures in a heterogeneous group of 15 patients. Material and Methods: In 8 patients indications for surgery were cystic lesions, in 3 patients intraventricular tumors, and in 4 patients occlusive hydrocephalus. The mean age was 39 years (range 9 - 76 years). The follow-up period ranged from 5 - 24 months (mean 10 months). Frameless neuronavigation was accomplished with the “operating arm system” in 10 cases and with the “optical tracking system” in 5 cases (RADIONICS, Burlington, USA). Results: In all 15 cases, neuronavigation sufficiently provided an…

AdultMaleVentriculostomymedicine.medical_specialtyNeuronavigationAdolescentmedicine.medical_treatmentIntraventricular tumorNeurosurgical ProceduresThird ventriculostomyHumansMedicineChildAgedRetrospective StudiesEndoscopesEndoscopic neurosurgeryBrain DiseasesPreoperative planningbusiness.industryCalibration ErrorEndoscopyEquipment DesignGeneral MedicineMiddle Agedmedicine.diseaseSurgeryHydrocephalusFemaleSurgeryNeurology (clinical)businessmin - Minimally Invasive Neurosurgery
researchProduct

Evaluation of surgical decision making and resulting outcome in patients with highly eloquent glioblastoma: Results of a multicenter assessment.

2017

Treatment of glioblastoma(GB) patients amenable only for a subtotal resection(STR) is controversial. Since outcome of patients is affected by surgical management, our aim was to assess surgical decision making and resulting outcome in patients with highly eloquent GBs.We retrospectively assessed GB patients with intended sub-total resection (STR) or stereotactic biopsy (STX) of 3 neurooncological centers operated between 2008 and 2013. A volumetric assessment of overall extent of resection(oEoR), presence of complications, new permanent neurological deficits(nPNDs) was performed. A central reviewer reassessed all cases blinded and gave recommendation on surgical management and on a potentia…

AdultMalemedicine.medical_specialtyStereotactic biopsyAdolescentClinical Decision-MakingExtent of resectionNeurosurgical Procedures03 medical and health sciencesYoung Adult0302 clinical medicinemedicineHumansIn patientAgedRetrospective StudiesAged 80 and overPreoperative planningmedicine.diagnostic_testbusiness.industryBrain NeoplasmsCentral ReviewerSubtotal ResectionGeneral MedicineMiddle Agedmedicine.diseaseSurgeryOutcome and Process Assessment Health Care030220 oncology & carcinogenesisNear total resectionSurgeryFemaleNeurology (clinical)businessGlioblastoma030217 neurology & neurosurgeryGlioblastomaClinical neurology and neurosurgery
researchProduct

Accuracy assessment of cone beam computed tomography-derived laboratory-based surgical templates on partially edentulous patients

2011

Objectives: The aim of the present prospective clinical study was to evaluate the match between the positions and axes of the virtually planned and the placed implants using laboratory-based surgical guides generated from cone beam computed tomography (CBCT). Materials and methods: A total of 132 implants were placed with the aid of 3D-based transfer templates in 52 consecutive partially edentulous patients between April 2008 and March 2010. After individual adaptation of the scan templates and CBCT scanning, the acquired data for virtual implant planning and simulation were processed using the med3D software program. After finalizing the virtual placement of the implants the radiographic t…

EdentulismCone beam computed tomographyPreoperative planningbusiness.industryRadiographyTreatment outcomeDentistrymedicine.diseaseImplant placementProspective clinical studyMedicineImplantOral SurgerybusinessClinical Oral Implants Research
researchProduct

Preserving the abductor mechanism in robotic THR: the influence of stem design and cutterpath.

2004

The tip of the greater trochanter is the attachment site for the abductor muscles of the hip joint. Its preservation in robotic and conventional THR is important for normal gait. The effect of different stem designs and robotic cutterpaths on the preservation of the trochanter tip is examined.One anatomical stem, one straight stem, and one stem specifically designed for robotic THR were implanted virtually in CT scans of osteoarthrotic hip joints using the Torch preoperative planning unit (URS-ortho). In transverse sections of the trochanter tip, dimensions of the trochanter area removed by the milling tool were recorded for each stem design and different cutterpaths (3-axis versus 5-axis m…

MaleGreater trochanterMaterials scienceAttachment siteArthroplasty Replacement HipUser-Computer InterfaceProsthesis FittingOsteoarthritismedicineHumansFemurMuscle SkeletalGaitPreoperative planningTrochantertechnology industry and agricultureStraight stemAnatomyRoboticsComputer Science ApplicationsMechanism (engineering)Normal gaitmedicine.anatomical_structureSurgery Computer-AssistedSurgeryMuscles of the hipFemaleHip JointFamily PracticeTomography X-Ray ComputedBiomedical engineeringComputer aided surgery : official journal of the International Society for Computer Aided Surgery
researchProduct

Extraoral surgical removal of an ectopic impacted third molar of the mandible. Report of a case

2020

Intraoral approach for the removal of impacted third molars represents a common surgical procedure for the specialized clinician. However, in some cases such as ectopic third molars, extraoral surgical removal seems to be inevitable. We present a step by step case of a 56 year old woman with an ectopic third molar of the lower jaw along with a cystic lesion, which were surgically removed by a submandibular approach. Postoperative clinical course was uneventful and there were no signs of facial nerve paresis. In such cases, appropriate preoperative planning must be made based on careful study of radiographic imaging and clinical examination. The more conservative technique that would minimiz…

Molarmedicine.medical_specialtyPhysical examinationCase Report02 engineering and technology03 medical and health sciencesCystic lesion0302 clinical medicinestomatognathic systemSurgical removalmedicineCystGeneral DentistryPreoperative planningmedicine.diagnostic_testbusiness.industryClinical courseMandible030206 dentistry021001 nanoscience & nanotechnologymedicine.disease:CIENCIAS MÉDICAS [UNESCO]SurgeryUNESCO::CIENCIAS MÉDICASOral Surgery0210 nano-technologybusiness
researchProduct

Comparison of iceball diameter and temperature distribution achieved with 3-mm accuprobe cryoprobes in porcine and human liver tissue and human color…

2000

Abstract We aimed to assess the thermal profile and size of iceballs produced by Accuprobe cryoprobes in fresh porcine and human liver and human colorectal cancer liver metastases in vitro to allow better planning of cryosurgical treatment of liver metastases. Iceballs were produced by a 20-min single freeze cycle using 8-mm cryoprobes in pig liver in a waterbath at 37°C ( n = 8) and 3-mm cryoprobes in pig liver ( n = 8), human liver ( n = 3), and human colorectal cancer liver metastases ( n = 8). The iceball diameters and the temperatures at different distances from the cryoprobe were measured. Mean iceball diameters produced by 8-mm cryoprobes in pig liver were 56.3 mm and varied from 38.…

Pathologymedicine.medical_specialtySwinemedicine.medical_treatmentIn Vitro TechniquesCryosurgeryGeneral Biochemistry Genetics and Molecular BiologyCryosurgeryMetastasisPorcine liverDistribution (pharmacology)MedicineAnimalsHumansPreoperative planningHuman liverbusiness.industryIceLiver NeoplasmsTemperatureGeneral Medicinemedicine.diseaseIn vitroLiverEvaluation Studies as TopicGeneral Agricultural and Biological SciencesbusinessColorectal NeoplasmsPig liverCryobiology
researchProduct

Preoperative Planning for Guidewires Employing Shape-Regularized Segmentation and Optimized Trajectories

2019

Upcoming robotic interventions for endovascular procedures can significantly reduce the high radiation exposure currently endured by surgeons. Robotically driven guidewires replace manual insertion and leave the surgeon the task of planning optimal trajectories based on segmentation of associated risk structures. However, such a pipeline brings new challenges. While Deep learning based segmentation such as U-Net can achieve outstanding Dice scores, it fails to provide suitable results for trajectory planning in annotation scarce environments. We propose a preoperative pipeline featuring a shape regularized U-Net that extracts coherent anatomies from pixelwise predictions. It uses Rapidly-ex…

Preoperative planningComputer sciencebusiness.industryDeep learningPipeline (computing)DiceMachine learningcomputer.software_genreTask (project management)Convex optimizationSegmentationArtificial intelligenceMotion planningbusinesscomputer
researchProduct

Propeller Flaps: A Review of Indications, Technique, and Results

2014

In the last years, propeller flaps have become an appealing option for coverage of a large range of defects. Besides having a more reliable vascular pedicle than traditional flap, propeller flaps allow for great freedom in design and for wide mobilization that extend the possibility of reconstructing difficult wounds with local tissues and minimal donor-site morbidity. They also allow one-stage reconstruction of defects that usually require multiple procedures. Harvesting of a propeller flap requires accurate patient selection, preoperative planning, and dissection technique. Complication rate can be kept low, provided that potential problems are prevented, promptly recognized, and adequate…

Propeller flaps defectsmedicine.medical_specialtyFINGERSettore MED/19 - Chirurgia PlasticaAXILLARY HIDRADENITISlcsh:MedicineLarge rangeReview ArticleGeneral Biochemistry Genetics and Molecular BiologySurgical FlapsMedicine and Health SciencesMedicineHumansComplication rateSurgical FlapsBREAST SURGERYPreoperative planningDissection techniqueGeneral Immunology and MicrobiologyVascular pediclebusiness.industryDissectionlcsh:RPropellerVERSATILITYNOSE RECONSTRUCTIONGeneral MedicineDEFECTSPlastic Surgery ProceduresARTERY PERFORATOR FLAPSSERIESSurgeryOrgan SpecificityBody regionbusinessPALMAR DIGITAL ARTERYCONSENSUSBioMed Research International
researchProduct

CT-Angiographie versus intraarterielle DSA bei Bauchaortenaneurysmen

1996

PURPOSE To evaluate if CT angiography is able to image all features necessary for the preoperative planning of abdominal aortic aneurysms (accessory renal arteries, stenoses or occlusions of renal and iliac arteries, patency of inferior mesenteric artery). METHODS CT angiography and DSA were performed on 27 patients with abdominal aortic aneurysms. CT angiography was performed using a protocol that covered the abdominal aorta and the pelvic arteries with a single spiral acquisition (contrast dose: 150 ml, collimation: 5 mm, table feed: 7.5 mm/s, increment of reconstruction: 2 mm). Maximum intensity projections (MIP) and axial scans were compared with the results of intraarterial DSA. RESULT…

Single administrationmedicine.medical_specialtyPreoperative planningmedicine.diagnostic_testbusiness.industryVascular diseaseAbdominal aortamedicine.diseaseInferior mesenteric arteryAbdominal aortic aneurysmAneurysmmedicine.arteryAngiographymedicineRadiology Nuclear Medicine and imagingRadiologybusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct